Depth rated

Depth rated device for long-range data transfers

Highly Configurable

Multiple configuration options and extra modules available to best-fit the particular application scenario

Directivity pattern

The beam pattern is optimal for transmissions in vertical and slant channels

 S2C R 12/24 USBLTECHNICAL SPECIFICATIONS

General

Operating Depth
Delrin
200 m
Aluminium Alloy
2000 m
Stainless Steel
2000 m
Titanium
6000 m
Operating Range
6000 m
Frequency Band
13 - 24 kHz
Transducer Beam Pattern
directional, 70 degrees

USBL

Slant Range Accuracy [1]
0.01 m
Bearing Resolution
0.1 deg
Nominal SNR
10 dB

Connection

Acoustic Connection
up to 9.2 kbit/s
Bit Error Rate
less than 10-¹⁰
Internal Data Buffer
1 MB, configurable
Host Interface [2]
Ethernet or RS-232
Interface Connector
up to 4 connectors,
Ethernet serial combinations

Power

Power Consumption [3]
Stand-by Mode
2.5 mW
Listen Mode
 5 - 285 mW
Receive Mode
 1.4 W
Transmit Mode
5.5 W, 250 m range
8 W, 500 m range
18 W, 1000 m range
57 W, max. available
Power Supply [4]
External
24 VDC (12 VDC)
Internal 
Rechargeable battery
5 Ah or 10 Ah

Physical

Housing Options
Delrin
Aluminium Alloy
Stainless Steel
Titanium
Dimensions [5]
Housing
Ø 110x218mm
USBL antenna
Ø 180x185mm
Total length
403 mm
Weight dry/wet

Delrin 8100/1400 g
Aluminium Alloy 9800/5300 g
Stainless Steel
13640/9540 g
Titanium 13420/8920 g

[1] Accuracy obtained in environment with a fl at sound velocity profi le, slant ranges estimated in local coodinate frame of the device  without the aid 
     of AHRS/GNSS and/or any other sensors contributing to the resulting accuracy. Slant range estimation is based  on the measured propagation time,               slant range accuracy depends on sound velocity profi le, refraction and signal-to-noise ratio. 
[2] One RS-232 Interface can be replaced with a RS-422 interface. Contact EvoLogics for more information! 
[3] Power consumption for RS-232 interface. Add 500 mW if an Ethernet interface is installed. Add 300 mW if the Wake-Up Module is installed.
      User-configurable Listen Mode is only available with a Wake-Up module installed. Power consumption in Listen Mode depends on Listen Mode settings. 
[4] 300 VDC available for 42/65 models. Contact EvoLogics for more information on power supply options! 
[5] Dimensions of a Delrin housing, other builds are slightly larger. Dimensions vary depending on housing type and installed options.
      Contact EvoLogics for more information on device dimensions and weights, request a drawing if necessary. 
[6] Internal Xsens® MTi AHRS (Attitude and Heading Reference System) compensates the changes of roll,
      pitch and heading. Power consumption increases by 400 mW with AHRS installed.
[7] The Wake Up Module is only compatible with RS-232 interface! It is not compatible with Ethernet or RS-422.
      2-channel Wake Up Module version reacts to incoming data on two serial interfaces. 
[8] The Power Switch is only compatible with RS-232 interface! It is not compatible with Ethernet or RS-422.

S2C R 12/24 USBL Directivity Pattern

Modules and Options

Internal AHRS [6]
iUSBL Configuration
Wake-Up Module [7]
Power switch [8]

Advanced Timekeeping
Module
SDM Version
Acoustic Release Device
Floatation Collar
Pressure Sensor
Cable-Mounted Transducer / Antenna
OEM-Version

 S2C R 12/24 USBLDOWNLOADS

The online version prevails in case of any discrepancy between the .pdf datasheet and online specifications.